62-296.507. Magnet Wire Coating  


Effective on Thursday, July 10, 2014
  • 1(1) Applicability. The emission limiting standard set forth in Rule 1162-296.507, 12F.A.C., shall apply to the ovens of magnet wire coating operations.

    23(2) Emission Limiting Standards. No owner or operator of a magnet wire coating oven subject to Rule 4062-296.507, 41F.A.C., may cause, allow, or permit the discharge into the atmosphere of any volatile organic compounds in excess of 1.7 pounds per gallon of coating (0.20 kilograms per liter), excluding water, delivered to the coating applicator from magnet wire coating operations.

    82(3) Control Technology. The emission limit under subsection 9062-296.507(2), 91F.A.C., shall be achieved by:

    96(a) The application of low solvent content coating technology; or,

    106(b) Incineration, provided that 90 percent of the volatile organic compounds (VOC measured as total combustible carbon) which enter the incinerator are oxidized to carbon dioxide and water.

    134(4) Test Methods and Procedures. All emissions tests performed pursuant to the requirements of this rule shall comply with the following requirements.

    156(a) Low Solvent Technology. The test method for volatile organic compounds shall be EPA Method 24, 172as described at 17540 C.F.R. Part 60, 179Appendix A-7, adopted and incorporated by reference at Rule 18862-204.800, 189F.A.C., 190or EPA 450/3-84-019, 193Procedures for Certifying Quantity of Volatile Organic Compounds Emitted by Paint, Ink, and Other Coatings (209http://www.flrules.org/Gateway/reference.asp?No=Ref-04298211), hereby adopted and incorporated by reference.

    218(b) Add-on Control Device.

    2221. Destructive. The test method for volatile organic compounds shall be EPA Method 25, 236as described at 23940 C.F.R. Part 60, 243Appendix A-7, adopted and incorporated by reference at Rule 25262-204.800, 253F.A.C., 254or Attachment 3 of EPA 450/ 2-78-041, 261Alternate Test Method for Direct Measurement of Total Gaseous Organic Compounds Using a Flame Ionization Analyzer, adopted and 279incorporated by reference in Chapter 62-297, F.A.C.

    2862. Non-destructive. The test method for volatile organic compounds shall be VOC Capture Efficiency Test Procedures 302as described at Rule 30662-297.450, 307F.A.C. The sampling time for each capture efficiency test run shall be at least 8 hours, unless otherwise approved by the Department pursuant to Rule 33262-297.620, 333F.A.C.

    334(c) Test procedures shall meet all applicable requirements of Chapter 62-297, F.A.C.

    346Rulemaking Authority 348403.061 FS. 350Law Implemented 352403.021, 353403.031, 354403.061, 355403.087 FS. 357History–Formerly 17-2.650(1)(f)7., 17-296.507, Amended 11-23-94, 1-1-96, 7-10-14.

     

Rulemaking Events:

Historical Versions(1)

Select effective date to view different version.