Department of Education, Florida State University  


  • BID #FAC30588 Hoffman Bldg(FSU)

    INVITATION TO BID

    The Florida State University Facilities Purchasing will receive sealed bids until the dates and times shown for the following projects. Bids may be brought to the bid opening or sent to:

                    Florida State University

                    Facilities Maintenance, Purchasing

                    114F Mendenhall Building A

                    Tallahassee, Florida 32306

    prior to bid opening. Bidder must reference bid number, opening date and time on outside of bid package to insure proper acceptance. Bids submitted by facsimile are not acceptable. For information relating to the Invitation(s) to Bid, contact the

    Bid Number:                          FAC30588-10

                                                    Reroofing Hoffman Laboratory

    Purchasing Agent:               B.J. Lewis, Facilities

    Mandatory Site Visit:           July 13, 2010, 10:00 a.m.

    Location:                                Hoffman Laboratory Building

    Special roofing prequalification submittal packages are to be turned in to the Architect at the time of the mandatory prebid meeting. The special prequalification submittal packages may be obtained from the Architect’s office prior to the prebid meeting.

    Public Bid Opening:     July 22, 2010, 2:00 p.m.

                                            FSU-Facilities Maintenance

                                            969 Learning Way

                                            125 Mendenhall, Building A

                                            Tallahassee, Florida 32306-4150

                                            Facilities Maintenance Purchasing

    Bid Documents: Reroofing Hoffman Laboratory Building

    Reroofing work at Hoffman Laboratory Building includes removing existing roofing and flashing system down to existing lightweight concrete deck. Prime and hot apply new temporary membrane/vapor barrier. Install new roof drains and additional new roof drains and cast iron piping. Install new tapered insulating lightweight concrete deck system with a minimum 1/4'' per foot slope and a minimum average aged insulation value of R-20. Mechanically fasten a base sheet and torch applies a new two ply mineral surfaced modified bitumen membrane. The system would be installed to meet FM I -110 wind uplift requirements and have an UL Class “A” rating in compliance with Florida State University Standards, the current Florida Building Code and the Roofing Manufacturer’s recommendations to provide a roofing manufacturer’s 20 or 25 year NDL system warranty to include the lightweight concrete deck. The work also includes prefinished aluminum counterflashing, coping, edge metal, flashing, installing new pipe equipment stands, and painting the rooftop rusted steel equipment, existing equipment stands, doors, frame and hatches. Also limited exterior waterproofing and maintenance repair of the mechanical screen walls above the low slope roof surface.

    Additive Alternate One: Install new prefinished aluminum coping on parapets.

    Contact Person:    Randy Lewis

                                    Project Architect MLD Architects

                                    211 John Knox Road, Suite 105

                                    Tallahassee, Florida 32303