62-672.700. Construction of New Phosphogypsum Stacks  


Effective on Monday, June 28, 1999
  • 1(1) Any new phosphogypsum stack or lateral expansion thereof as defined in subsection 1462-673.200(9), 15F.A.C., shall be designed in accordance with the minimum standards of Chapter 62-673, F.A.C., with an overall factor of safety of 1.5 for any potential failure surface encompassing the impoundment on top of the stack and passing through the gypsum slope or bottom liner interfaces, or extending into earthen material in contact with the bottom liner.

    71(2) The maximum height of a starter dike for new phosphogypsum stacks or lateral expansions thereof shall be equal to or lower than the height of the associated lined perimeter dike.

    102Specific Authority 104403.4155 FS. 106Law Implemented 108403.4155 FS. 110History–New 6-28-99.

     